ENGINE SERVICE MODE
SM 5-61 G104
Service
Tables
5812 [Tel. No. Setting]
5812 001 Service *CTL
Sets the telephone number for a service
representative. This number is printed on the
Counter List, which can be printed with the
user’s “Counter” menu. This can be up to 20
characters (both numbers and alphabetic
characters can be input).
5812 002 FAX TEL No. *CTL
Sets the fax or telephone number for a
service representative. This number is
printed on the Counter List, which can be
printed with the user’s “Counter” menu if the
Meter Charge mode is selected with SP5-
930-1. This can be up to 13 characters (both
numbers and alphabetic characters can be
input).
5813 [Power Freqency]
5813 001 - Displays the power frequency.
[0 to 100 / 0 / 1 Hz/step] Not used
5814 [Power Voltage]
5814 001 Detected Voltage - Displays the detected power voltage.
[0 to 400 / 0 / 1 V/step] Not used
5816 [Remote Service]
5816 001 I/F Setting *CTL [0 to 2 / 2 / 1/step] Alphanumeric
0: Off, 1: CSS
2: Network
(The remote service function is on.)
5816 002 CE Call *CTL [0 to 1 / 1 / 1/step]
0: Start, 1: End
5816 003 Function Flag *CTL [0 to 1 / 0 / 1/step]
0: Off (The remote service function is
disabled.)
1: On (The remote service function is
enabled.)
5816 006 Device Informati *CTL
Shows or does not show the device
information in the User Tools.
[0 to 1 / 0 / 1/step]
0: Not displayed, 1: Displayed
5816 007 SSL Disable *CTL [0 to 1 / 0 / 1/step]
0: On, 1: Off
5816 008 RCG Connect Time *CTL
Sets the timeout counter for the remote
connection.
[1 to 90 / 10 / 1 second/step]
5816 009 RCG Write Timeou *CTL
Sets the timeout counter for writing
processing.
[0 to 100 / 60 / 1 second/step]