ENGINE SERVICE MODE
G104 5-94 SM
9908 [Background Po.] Background potential
9908 001 Upper Limit *EGB
Adjusts the upper limit vale of background
potential.
[0 to 300 / 130 / 1/step]
9908 002 Lower Limit *EGB
Adjusts the lower limit vale of background
potential.
[0 to 300 / 130 / 1/step]
9910 [Charge Output]
9910 001 Charge Output - Performs the charge output.
[Toner Fill Up]
9910 003 [All] - Fills up the toner for all colors.
[TC Initial] Toner Cartridge Initial
9910 004 [All] -
9910 005 [K] -
9910 006 [M] -
9910 007 [C] -
9910 008 [Y] -
Initializes the all toner bottles for each mode.
[Toner Fill Up]
9910 010 [K] -
9910 011 [M] -
9910 012 [C] -
9910 013 [Y] -
Fills up the toner for each color.
9910 020 Upper Limit *EGB
Adjusts the upper limit for filling up the toner.
If the toner is detected for [N] times, the
toner fill up mode ends.
[N] can be adjusted with this SP9910-020.
[1 to 5 / 3 / 1/step]
9911 [TC Initial] Toner Cartridge Initial
9911 001 Maximum Repeat *EGB [1 to 30 / 15 / 1/step]]
9911 002 Threshold *EGB [1 to 100 / 20 / 0.01V/step]
9912 [ST Sensor]
9912 001 read - Detects ST sensor output.