Service Call Conditions
SM 4-15 G160/G161
G160/G161
SC
[Level]
Symptom Possible Cause/Required Action
movement of actuator at the
sensor while the polygon
motor rotates.
Disconnected connector of transfer belt
contact sensor or motor
Disconnected cable
1. Replace the transfer belt contact
sensor.
2. Replace the transfer belt contact motor.
Transfer roller contact error
452
[D]
The transfer roller contact
sensor does not detect the
movement of actuator at the
sensor while the polygon
motor rotates.
Defective transfer roller contact sensor
Defective transfer roller contact motor
Defective IOB
1. Replace the transfer roller contact
sensor.
2. Replace the transfer roller contact
motor.
3. Replace the IOB.
High Voltage Power 1: High voltage output error
490
[D]
Error signal is detected for
10 times consecutively.
One of the DC bias outputs for each PCU is
shorted or one of the transfer belt bias outputs
for [Y], [M] and [C].
Power leaking
Defective connection
Disconnected cable
Defective PCU
Defective High Voltage Power 1
1. Replace the High Voltage Power 1.
2. Reset the cables and components.
3. Replace the PCU.
High Voltage Power 2: High voltage output error
491
[D]
Error signal is detected for
10 times consecutively.
One of the separation bias output,
development bias output and transfer belt
cleaning bias output is shorted or one of the
transfer belt bias output for [K] and transfer
roller bias output is shorted.
Power leaking