Service Call Conditions
SM 4-17 G160/G161
G160/G161
SC
[Level]
Symptom Possible Cause/Required Action
that is less than 67
degrees for 9 seconds is
detected five times
consecutively.
The fusing temperature
does not reach the print
ready temperature within
15 seconds after the
fusing lamp was
controlled.
Incorrect power supply input at the main
power socket
Defective fusing lamp
High temperature detection: Software
543
[A]
The thermistor detects
230°C for 0.2 seconds.
Defective thermistor
Defective I/O board
Defective EGB
High temperature detection: Hard
544
[A]
The thermistor detects
250°C.
Defective thermistor
Defective I/O board
Defective EGB
Defective fusing unit, PSU, or EGB
1. Replace the fusing unit.
2. Replace the PSU.
Heating lamp error
545
[A]
The fusing lamp is
full-powered for 8 seconds
after the heating roller
reaches the print ready
temperature.
Deformed thermistor
Thermistor coming off
Defective fusing lamp
Zero cross error
547
[D]
The zero cross signal is
detected three times
even though the heater
relay is off when turning
on the main power.
Defective fusing lamp relay
Defective fusing lamp relay circuit
Unstable power supply
1. Check the power supply source.
2. Replace the PSU.