Service Mode Table
G160/G161 5-156 SM
[Time Adjust.] Time Adjustment
9003
Adjusts the current year, month, date, hour, and minute.
9003 001 Year -
[0 to 99 / 0 / 1 y/step]
9003 002 Month -
[1 to 12 / 1 / 1 m/step]
9003 003 Date -
[1 to 31 / 1 / 1 d/step]
9003 004 Hour -
[0 to 23 / 0 / 1 hour/step]
9003 005 Minute -
[0 to 59 / 0 / 1 m/step]
[Gamma] Gamma Table
(Process Speed, [Color]) RS: Regular Speed, LS: Low Speed
9903
Adjusts the gamma table lists for each mode.
9903 028 OHP: K3 *EGB
9903 031 OHP: M3 *EGB
9903 034 OHP: C3 *EGB
9903 037 OHP: Y3 *EGB
[0 to 31 / 7 / 1/step]
[Vpp]
9906
Adjusts the AC charge bias correction for each environment.
9906 001 Vpp1: LL *EGB
[0 to 3000 / 1950 / 1 V/step]
9906 002 Vpp2: LL *EGB
[0 to 3000 / 2200 / 1 V/step]
9906 003 Vpp1: ML *EGB
[0 to 3000 / 1780 / 1 V/step]
9906 004 Vpp2: ML *EGB
[0 to 3000 / 2030 / 1 V/step]
9906 005 Vpp1: MM *EGB
[0 to 3000 / 1770 / 1 V/step]
9906 006 Vpp2: MM *EGB
[0 to 3000 / 2020 / 1 V/step]
9906 007 Vpp1: MH *EGB
[0 to 3000 / 1810 / 1 V/step]
9906 008 Vpp2: MH *EGB
[0 to 3000 / 2060 / 1 V/step]
9906 009 Vpp1: HH *EGB
[0 to 3000 / 1770 / 1 V/step]
9906 010 Vpp2: HH *EGB
[0 to 3000 / 2020 / 1 V/step]
[Background Po.] Background Potential
9908
Adjusts the upper or lower threshold for disabling the charge bias.
9908 001 Upper Limit *EGB
9908 002 Lower Limit *EGB
[0 to 300 / 130 / 1/step]