SERVICE PROGRAM MODE
G108 5-14 SM
5812 Tel. No. Setting ( 5.1.5)
Service 5812 001*
Sets the telephone number for a service representative. This number is printed
on the counter list, which can be printed with the user’s "Counter" menu. This
can be up to 20 characters (both numbers and alphabetic characters can be
input).
FAX TEL No. 5812 002*
Sets the fax or telephone number for a service representative. This number is
printed on the Counter List, which can be printed with the user’s "Counter"
menu if the Meter Charge mode is selected with Engine SP5-930-1. This can
be up to 13 characters (both numbers and alphabetic characters can be input).
5816 Remote Service Japan Only
5816 001* I/F Setting
[0 ∼ 1 / 1 / 1/step]
0: Off
1: Network (The remote service function is on.)
5816 002* CE Call
[0 ∼ 1 / 1 / 1/step]
0: Start, 1: End
5816 003* Function Flag
[0 ∼ 1 / 1 / 1/step]
0: Off (The remote service function is disabled.)
1: On (The remote service function is validated.)
Device Information
[0 ∼ 1 / 0 / 1/step]
0: Not displayed, 1: Displayed
5816 006*
Displays or does not display the device information in the User Tools.
5816 007* SSL Disable
[0 ∼ 1 / 0 / 1/step]
0: Enabled, 1: Disabled
RCG Connect Time
[1 ∼ 90 / 10 / 1 second/step]
5816 008*
Sets the timeout counter for the remote connection.
RCG Write Timeout
[0 ∼ 100 / 60 / 1 second/step]
5816 009*
Sets the timeout counter for the writing processing.
RCG Read Timeout
[0 ∼ 100 / 60 / 1 second/step]
5816 010*
Sets the timeout counter for the reading processing.
Port 80 Enable
[0 ∼ 1 / 0 / 1/step]
0: Disables, 1: Enables
5816 011*
Enables or disables the access to the SOAP method via port 80.
5821 Remote Service Address
5821 001* CSS-PI Device Code
[0 ∼ 4 / 0 / 1/step] DFU
RCG IP Address
[00000000h ∼ FFFFFFFFh / 00000000h /
1/step]
5821 002*
Specifies the IP address of the RCG (Remote Communication Gate).