G133 4-20 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
The shutter open sensor loses the "ON" signal after the shutter was
closed.
Defective motor
Change of load to shutter motor
Replace the shutter on the laser optics housing unit.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Shutter overrun error 2: Open
The shutter open sensor detects "ON" after SC 291 has occurred.
Defective motor
Change of load to shutter motor
295 D
Replace the shutter on the laser optics housing unit.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Shutter open/close sensor error
Both shutter open sensor and close sensor detect "ON" at the same
time.
Broken harness(es) of the shutter open/close sensors
296 D
Replace the shutter on the laser optics housing unit.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
300 D AC charge output error [K]
301 D AC charge output error [M]
302 D AC charge output error [C]
303 D AC charge output error [Y]