Service Mode Table
G133 5-38 SM
[1 to 5 / / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
011 Previous Temp.: Display *ENG
Displays the previous temperature.
[0 to 100 / – / 1°C/step]
012
Previous Relative
Humidity: Display
*ENG
Displays the previous relative humidity.
[0 to 100 / – / 1%RH/step]
013
Previous Absolute
Humidity: Display
*ENG
Displays the previous absolute humidity.
[0 to 100 / – / 0.01 g/m
3
/step]
[Color Registration Correction] FA
2101
These values are the parameters for the manual and automatic line position
adjustment and are adjusted at the factory. However, you must input a value
for SP2101-001 after replacing the laser optics housing unit. For details, see
"p.3-3 "Laser Optics Housing Unit"" in the "Replacement and Adjustment"
section. The value should be provided with the new laser optics housing unit.
001 Main Dot: Bk *ENG
002 Main Dot: M *ENG
003 Main Dot: C *ENG
004 Main Dot: Y *ENG
[–512 to 511 / 0 / 1 dot/step]
005 Sub Line: Bk *ENG
006 Sub Line: M *ENG
007 Sub Line: C *ENG
008 Sub Line: Y *ENG
[–16384 to 16383 / 0 / 1 line/step]
2102 [Magnification Adjustment] DFU
001
Main Mag.: High Speed:
Bk
*ENG
These are results of the main scan
length adjustment.