Service Mode Table
G133 5-156 SM
010 Result: Latest 9 *ENG
3013 [T Sensor Initial Set: Execution] Developer Initialization Setting
001 Execution: ALL -
002 Execution: COL (MCY) -
003 Execution: Bk -
004 Execution: M -
005 Execution: C -
006 Execution: Y -
DFU
3014 [T Sensor Initial Set Result: Display] Developer Initialization Result: Display
Display: YCMK *ENG
[0 to 9999 / - / - ]
1: Success
2 to 9: Failure
001
Displays the developer initialization result. See section "p.4-3 "Developer
Initialization Result"" for details on the meaning of each code.
All colors are displayed. Values are displayed in the order Y C M Bk.
e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others
succeeded.
3015 [Forced Toner Supply] Forced Toner Supply ([Color])
001 Execution: ALL -
002 Execution: COL (MCY) -
003 Execution: Bk -
004 Execution: M -
005 Execution: C -
Executes the manual toner supply to the
development unit.