Service Mode Table
SM 5-159 G133
Service
Tables
005-008 Sets the execution flag for the toner supply mode for each color.
005 Execution Flag: Bk *ENG
006 Execution Flag: M *ENG
007 Execution Flag: C *ENG
008 Execution Flag: Y *ENG
[0 or 1 / 0 / 1/step]
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD
sensor initialization.
3041 [Process Control Type]
Voltage Control *ENG
[0 or 1 / 1 / 1/step ] Alphanumeric
0: FIXED (Use the fixed values for the
charge DC bias and development DC bias
set with SP2-005 and SP2-229.)
1: CONTROL
001
Enables or disables potential control.
LD Power Control *ENG
[0 or 1 / 1 / 1/step] Alphanumeric
0: FIXED (at the value in SP2221-xxx)
1: CONTROL (adjusted by process control)
002
Selects the LD power control mode.
Pre-ACC Process
Control
*ENG
[0 to 2 / 2 / 1/step]
0: Not Executed
1: Process Control
2: TC Control (TD Adjustment)
3: Not used
004
Selects the process control mode that is done before ACC.
3043 [TD Adjustment Mode]
Repeat Number: Power ON *ENG
[0 to 9 / 4 / 1 time/step]
001
Specifies the maximum number of repeats of the toner density adjustment at
power on.