006 Developer Mixing *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
007 Process Control *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
008 MUSIC *ENG
[0 to 2 / 0 / 1/step]
0: OFF. 1: ON (once), 2: ON (twice)
009 Drum Phase Adj. *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
010 Charge AC Control *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
011
Blade Damage
Prevention
*ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
[Toner End Prohibition Setting]
3519
Enables or disables each adjustment at toner near end.
001 Process Control *ENG
002 MUSIC *ENG
003 TC Adj. *ENG
[0 or 1 / 1 / 1/step]
0: Permit (adjustment is done even toner
near end condition)
1: Forbid (adjustment is not done at toner
near end condition)
[Initial Process Control Setting]
3522
Adjusts the threshold for the process control at power on.
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at power on is executed.
002 Non-use Time Setting *ENG
[0 to 1440 / 360 / 1 minute/step]
003 Temperature Range *ENG
[0 to 99 / 10 / 1°C/step]