Service Mode Table
SM 5-191 G133
Service
Tables
009 Bk (Standard Target Set) *ENG
Displays the standard target
development gamma for each color.
[0 to 5 / 0.9 / 0.01 mg/cm
2
/kV /step]
010 M (Standard Target Set) *ENG
011 C (Standard Target Set) *ENG
012 Y (Standard Target Set) *ENG
[0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
013 Environmental Correction *ENG
Turns on or off the environmental
correction for target development
gamma.
[0 or 1 / 1 / - ]
0: Not Correct, 1: Correct
[Vk Display]
3612
Displays Vk for each color.
001 Bk *ENG
002 M *ENG
003 C *ENG
004 Y *ENG
[-300 to 300 / - / 1 V/step]
[Development DC Control: Display]
Plain: 205 mm/sec, Thick 1: 115 mm/sec, Thick 2 & FINE: 77 mm/sec
3621
Displays the development DC bias adjusted with the process control for each
line speed and color.
001 Plain: Bk *ENG
002 Plain: M *ENG
003 Plain: C *ENG
004 Plain: Y *ENG
[0 to 700 / 550 / 1 -V/step]