Service Mode Table
SM 5-233 G133
Service
Tables
[Permit ROM Updating] DFU
5886
This SP determines whether the ROM can be updated.
001 - *CTL
[0 or 1 / 0 / 1/step]
0: ON, 1: OFF
[Plug & Play Maker/Model Name] Plug & Play Name Selection
5907
Specifies the manufacturer and model name. These names are registered in
the NVRAM. If the NVRAM becomes defective, these names should be
re-registered.
001 Plug/Play *ENG
[0 to 11 / 0 / 1 /step ] FA
0: RICOH Aficio SP C811DN
1: SAVIN CLP240D
2: Gestetner C7640nD
3: NRG SP C811DN
4: infotec IPC 4040DN
5: LANIER LP440c/SP C811DN
5924 [SDK Apli Display]
SDK Apli Display *CTL
[0 or 1 / 0 / 1/step]
0: Not display, 1: Display
001
Enables or disables the LCD display of the SDK application.
5930 [Meter Click Ch.] Meter Click Charge
5930 001 Meter Click Ch. *EGB
Enables or disables the Meter Charge
mode. When enabling the Meter Charge
mode, the “Counter” menu is added to the
user menu.
[0 or 1 / 0 / -]
0: OFF, 1: ON