Service Mode Table
G133 5-296 SM
8 999 13 Duplex
8 999 14 Coverage: Color (%)
8 999 15 Coverage: BW (%)
8 999 16 Coverage: Color Print Page (%)
8 999 17 Coverage: BW Print Page (%)
SP9-XXX: Others
9511
Skew Origin Set *CTL
001 M: Skew Motor
002 C: Skew Motor
003 Y: Skew Motor
These SPs reset the skew correction value
(SP2-119-001 to -003) to "0".
9911 [Pressure Roller Condition]
Normal: Threshold:
Upper Limit
*ENG
[0 to 200 / 140 / 1 deg/step]
001
Specifies the threshold temperature of the pressure roller between M (middle)
and H (high). This SP is referred when the input voltage of the IH inverter is
more than 93% (adjustable with SP1-916-026).
Normal: Threshold:
Lower Limit
*ENG
[0 to 200 / 120 / 1 deg/step]
002
Specifies the threshold temperature of the pressure roller between L (low) and
M (middle). This SP is referred when the input voltage of the IH inverter is more
than 93% (adjustable with SP1-916-026).
003
Coefficient: Low *ENG
[0 to 3 / 2 / 1 /step]
0: No effect
1: Normal