SC Tables: SC8xx -1
G179 4-30 SM
821
CTL
D
Self-diagnostics error: ASIC
[XXXX]: Detailed error code
ASIC detection error
The I/O ASIC for system control is not detected.
[0B06]
Defective ASIC
Defective North Bridge and PCI I/F
Replace the controller board.
For more details about this SC code error, execute SP5990 to print an SMC report
so you can read the error code. The error code is not displayed on the operation
panel.
822
CTL
B
Self-diagnostic error: HDD
Check performed only when HDD is installed:
HDD device busy for over 31 s.
After a diagnostic command is set for the HDD, but the device remains
busy for over 6 s.
[3003]
HDD defective
HDD harness disconnected, defective
Controller board defective
No response to the self-diagnostic command from the ASIC to the HDDs.
[3004]
HDD defective
Self-diagnostic error : NVRAM
NVRAM device does not exist, NVRAM device is damaged, or NVRAM
socket damaged.
824
CTL
D
NVRAM defective
Controller board defective
NVRAM backup battery exhausted
NVRAM socket damaged