Drum Charge
SM 6-21 G179
Detailed
Descriptions
6.6.3 ID SENSOR PATTERN PRODUCTION TIMING
When the machine temperature is less than 16°C at power on, an ID sensor pattern is
created after the main machine is powered on, and after finishing a job of 10 or more
sheets.
The ID sensor pattern production interval can be adjusted with SP2210-001 (ID Sensor
Pattern Interval).
6.6.4 DRUM CHARGE ROLLER CLEANING
The drum charge roller [A] (always in contact with the drum), gets dirty easily.
The brush roller [B] remains in contact with the charge roller to clean the charge roller.