EasyManua.ls Logo

Ricoh Gestetner 5430 - Jam Detection; Master Eject Jam (E Jam Location Indicator); Picking up the Used Master from the Drum; Just after Turning on the Main Switch

Ricoh Gestetner 5430
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JAM DETECTION 31 October 2001
6-44
6.10 JAM DETECTION
6.10.1 MASTER EJECT JAM (E JAM LOCATION INDICATOR)
Picking up the used master from the drum
Jam check timing: When the clamper open sensor is on (clamper open).
Check 1: If the master eject motor is still on after 1.0 second, and the master eject
sensor doesn’t detect the master, the machine goes on to check 2.
Check 2: When the clamper opens and closes again, and the drum has rotated 1.0
s, if the master eject sensor doesn’t detect the master, the E jam
indicator will light.
Compressing the used master
Jam check timing: When moving the pressure plate.
Check: If the master eject sensor detects a master when the pressure plate limit
sensor turns on (pressure plate at lower limit), the E jam indicator lights.
Just after turning on the main switch
Jam check timing: Just after the main switch has been turned on.
Check: If the master eject sensor is on (master detected), the E jam indicator
lights.
1.0 s
Main motor (30 rpm)
1.0 s
Clamper
Master eject motor
Master eject sensor
Open
Close
Open
Close
Check 1
Check 2
C238D532.WMF
Pressure plate HP sensor
Check
Master eject sensor
Pressure plate motor
Pressure plate limit sensor
C238D533.WMF