31 October 2001 MAIN MENU NO.7: MEMORY CLEAR
5-13
Service
Tables
5.8 MAIN MENU NO.7: MEMORY CLEAR
5.8.1 SP TABLE
No. Menu Items Default Settings
7-1 Factory settings clear No No / Clr ( 5.8.3)
7-2 All settings clear No No / Clr
7-3 Total counter clear No No / Clr
7-4 Jam/Error data clear No No / Clr
5.8.2 SP7: HOW TO CLEAR
1. Using the number “1” key or the scroll keys, select “Clr”.
2. Press the Enter key.
3. When the clear is completed, ring the beeper.
5.8.3 SP7-1: FACTORY SETTINGS CLEAR
This resets all SP settings except for the following SP numbers.
SP2-20: Destination settings
SP3-01: Present time
SP6-All: Adjustments