SC8xx: Overall System
SM 6-91 D0CA/D0C9/D0C8/D0CB
Troubleshooting
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
replace the RAM-DIMM).
[0302] Optional Memory 0 Structural Error
Every time the main power is turned ON, the structure of the optional RAM is
checked.
If an error is detected at this point, the self-diagnostic module will not check
the optional RAM.
-
-
[0401] Optional RAM1: Verify Error
In this machine, the standard RAM on the controller (2GB) is divided into the
resident RAM (1GB) and the optional RAM (1GB).
Defective memory device (on the Controller Board (PCB24)).
1. Replace the Controller Board (PCB24).
[0402] Optional RAM1: Structure Error
Every time the main power turns on, structures of the optional RAM are
checked. If an error is detected at this time, the self-diagnostic module will
not check the optional RAM.
-
-
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC833-00 D Self-diagnostic Error: Engine I/F ASIC
[XXXX]: Detailed error code
[0F30] Engine I/F ASIC Detection Error
ASIC (Mandolin) for engine control could not be detected.
ASIC (Mandolin) error
1. Replace the Engine I/F board (mother board).
[50B1] Video Device: Clock Generator Detection Error
Could not initialize or read the bus connection.
Defective connection bus
Defective SSCG
1. Replace the Engine I/F board (mother board).
[50B2] Video Device: Clock Generator Verify Error
Value of the SSCG register is incorrect.
Defective connection bus
Defective SSCG
1. Replace the Engine I/F board (mother board).