SC8xx: Overall System
D0CA/D0C9/D0C8/D0CB 6-92 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC834-00 D Self-diagnostic error: Optional memory
[5101] Engine I/F optional memory verify error
An error occurs after write/verify check for optional RAM on the engine I/F
board (mother board).
Defective memory device
Replace the Engine I/F board (mother board).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC835-00 B Self-diagnostic Error: Centronic Device
[xxxx]: Detailed error code
[1102] Verify Error
The loopback connector is connected but check results is an error.
IEEE1284 connector error
Centronic loopback connector defective
1. Replace the Controller Board (PCB24).
[110C] DMA Verify Error
The loopback connector is connected but check results is an error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector is defective
1. Replace the Controller Board (PCB24).
[1120] Loopback Connector Not Detected
Centronic loopback connector is not connected for detailed self-diagnostic
test.
Centronic loopback connector not connected correctly
Centronic loopback connector is defective
ASIC device is defective
1. Connect the centronic loopback connector
2. Replace the centronic loopback connector
3. Replace the Controller Board (PCB24).