SC Tables
SM Appendix 3-5 M065/M066
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
230 D
FGATE ON error: K
The PFGATE ON signal does not assert within 5 seconds after
processing the image in normal job or MUSIC for start position [K].
Defective ASIC
Poor connection between controller and BCU.
Defective BCU
1. Check the connection between the controller board and the BCU.
2. Replace the BCU.
3. Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
231 D
FGATE OFF error: K
The PFGATE ON signal still asserts within 5 seconds after
processing the image in normal job or MUSIC (line position
adjustment) for end position [K].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
232 D
FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after
processing the image in normal job or MUSIC (line position adjustment)
for start position [Y].
See SC 230 for troubleshooting details.