System Service Mode
M065/M066 8-20 SM Appendix
020 SP 3: Ends *ENG
021 Envir. Correct:Low *ENG
[-100 to 100 / 10 / 1 %]
022 Envir. Correct:High *ENG
[-100 to 100 / 0 / 1 %]
023 FF. Correct: Center *ENG
024 FF Correct:Ends *ENG
[FF Correct Time]
025
FF Correct Time *ENG
[0 to 60 / 5 / 1 sec]
Specifies the FF duty correction time after the fusing/ paper exit motor has
started to rotate in each print mode.
[FF Control thresh]
Specifies the offset temperature for turning off the FF duty correction.
026 Offset:Center *ENG
[0 to 50 / 25 / 1 deg]
027 Offset:Ends *ENG
[FF Start Time]
Specifies the start time of the FF duty correction after FGATE has been "ON".
028 Fgate Timer:FC:Full *ENG
[0 to 10000 / 400 / 1msec]
029 Fgate Timer:FC:Half *ENG
[0 to 10000 / 3700 / 100msec]
030 Fgate Timer:BW:Full *ENG
[0 to 10000 / 0 / 100msec]
031 Fgate Timer:BW:Half *ENG
[0 to 10000 / 800 / 100msec]
[FF Correct Time]
Specifies the additional time to the FF duty correction time for each lien speed.
Full: Full speed, Half: Half speed
032 Time Set:Full *ENG
[-5000 to 5000 / 0 / 100msec]
033 Time Set:Half *ENG
[Fgate Timer]
Specifies the additional duty to the heating roller fusing lamp for each paper type. These
values are added to the duty decided by the PID control.