System Service Mode
SM Appendix 8-21 M065/M066
Appendix:
SP Mode
Tables
034 FC:Middle *ENG
[0 to 10000 / 1000 / 100msec]
035 BK:Middle *ENG
[0 to 10000 / 0 / 100msec]
[Correct Time Set]
036 Middle *ENG
[-5000 to 5000 / 0 / 100msec]
[Fusing FF Control]
Specifies the additional duty to the heating roller fusing lamp for each paper type. These
values are added to the duty decided by the PID control.
050 Plain2:Center *ENG
[0 to 100 / 60 / 1 %]
051 Plain2: End *ENG
052 F:Plain1: Center *ENG
[0 to 100 / 20 / 1 %]
053 F:Plain1: End *ENG
054 F:M-Thick: Center *ENG
[0 to 100 / 30 / 1 %]
055 F:M-Thick: End *ENG
056 F:Thick1: Center *ENG
057 F:Thick1: End *ENG
058 F:Special1: Center *ENG
059 F:Special1: End *ENG
060 F:Special2: Center *ENG
061 F:Special2: End *ENG
062 F:Plain2: Center *ENG
[0 to 100 / 20 / 1 %]
063 F:Plain2: End *ENG