System Service Mode
SM Appendix 8-39 M065/M066
Appendix:
SP Mode
Tables
2111 [Line Pos. Ajust]
001 Execute: Mode a -
Executes the fine line position adjustment
twice.
If this SP is not completed (NG is
displayed), do SP2111-003 first and then try
this SP again.
002 Execute:Mode b -
Executes the fine line position adjustment
once.
If this SP is not completed, do SP2111-003
first and then try this SP again.
003 Execute:Mode c -
Executes the rough line position adjustment
once.
After doing this SP, make sure to execute
SP2111-001 or -002. Otherwise, the line
position adjustment is not perfectly done.
004 Execute:Mode d -
Rough adjustment and fine adjustment,
once each.
2112 [ID Sensor Test] ID Sensor Check FA
001 Execute
This SP is used to check the ID sensors at
the factory. The results of this SP are
displayed in SP2140 to SP2145.
2117
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C or Y.
001 Pulse: C *ENG
[–100 to 100 / 0 / 1 pulse/step]
002 Pulse: M *ENG
003 Pulse: Y *ENG