System Service Mode
M065/M066 8-40 SM Appendix
2118 [Skew Adjustment]
001 Execute: C *ENG
Changes the current skew adjustment
values to the values specified with SP2117.
002 Execute: M *ENG
003 Execute: Y *ENG
2119
[Skew Adjustment Display]
Displays the current skew adjustment value for each skew motor.
001 C *ENG
[–75 to 75 / 0 / 1 pulse/step]
002 M *ENG
003 Y *ENG
2140
[ID Sensor Check Result]
Displays the maximum result values of the ID sensor check.
Front, Center, Rear: ID sensors for the automatic line position adjustment and
the process control
001 PWM: Bk *ENG
[0 to 1024 / 0 / 1/step]
002 PWM: C *ENG
003 PWM: M *ENG
004 PWM: Y *ENG
005 PWM: Front *ENG
006 PWM: Center *ENG
007 PWM: Rear *ENG