System Service Mode
SM Appendix 8-167 M065/M066
Appendix:
SP Mode
Tables
2880
[Special 3: Env. Correct Table] DFU
Low: 85 mm/sec
015 Separation DC: Low: 1st *ENG
[1 to 100 / 30 / 1 /step]
016 Separation DC: Low: 2nd *ENG
[SP 3: Edge-Env. Correct] DFU
019 Separation DC: Low: 1st *ENG
[1 to 100 / 30 / 1 /step]
020 Separation DC: Low: 2nd *ENG
2902
[OPC Drum Rev Time] DFU
Adjusts the time for how long the drum motor reverses after job end.
002 All: FC *ENG
[0 to 800 / 70 / 10 msec/step]
003 DevRev: FC *ENG
004 DevRev: Bk *ENG
2904
[Image Transfer Rev Time] DFU
Adjusts the time for how long the image transfer belt motor reverses after job
end.
003 All *ENG
[0 to 800 / 70 / 10 msec/step]

Table of Contents