System Service Mode
M065/M066 8-172 SM Appendix
SP3-XXX (Process)
3011 [Process Cont. Manual Execution]
001 Normal Procon -
[0 or 1 / 0 / 1 /step]
Executes the normal process control
manually (potential control).
Check the result with SP3-325-001 after
executing this SP.
002 Toner Density Adjst -
[0 or 1 / 0 / 1 /step ]
Executes the toner density adjustment
manually. Check the result with
SP3-325-001 after executing this SP.
003 Procon Pre-ACC -
[0 or 1 / 0 / 1 /step ]
Executes the process control that is
normally done before ACC.
The type of process control is selected with
SP3-041-004.
004 With Full MUSIC -
[0 or 1 / 0 / 1 /step ]
Executes the process control that is
normally done at the same time as MUSIC.
This SP does the MUSIC (line position
adjustment) twice.
005 With Normal MUSIC -
[0 or 1 / 0 / 1 /step ]
Executes the process control that is
normally done at the same time as MUSIC.
This SP does the MUSIC (line position
adjustment) once.