System Service Mode
SM Appendix 8-177 M065/M066
Appendix:
SP Mode
Tables
3041 [Process Control Type]
001
Bias Control *ENG
[0 or 1 / 1 / 1/step ] Alphanumeric
0: FIXED (Use the fixed values for the charge
DC bias and development DC bias set with
SP2-005 and SP2-229.)
1: CONTROL
Enables or disables the process control.
002
LD Power Control *ENG
[0 or 1 / 1 / 1/step] Alphanumeric
0: FIXED (at the value in SP2221-xxx)
1: CONTROL (adjusted by process control)
Selects the LD power control mode.
003
Auto Control
Prohibition Set
*ENG
[0 or 1 / 0 / 1/step]
DFU
004
Pre-ACC Process
Control
*ENG
[0 to 2 / 2 / 1/step]
0: Not Execute
1: Process Control
2: TC Control
Selects the process control mode that is done before ACC.
005
Pattern Caluculation
Method
*ENG
[0 to 2 / 0 / 1/step]
0: FIXED
1: INITIALIZED
2: CALCULATED