System Service Mode
SM Appendix 8-217 M065/M066
Appendix:
SP Mode
Tables
009 Drum Phase Adj. *ENG
[0 or 1 / 0 / 1/step]
0: OFF. 1: ON
010 Charge AC Control *ENG
011 Blade Damage Prevention *ENG
012 Vsg Average Error *ENG
[0 or 1 / 0 / 1/step]
Sets "1", when the following values
shows.
Vsg_reg_ave:
3.5 Vsg_reg_ave 4.5 or
Vsg_dif_ave:
0.0 Vsg_dif_ave 0.5
3519
[Toner End Prohibition Setting]
Enables or disables each adjustment at toner end.
001 Process Control *ENG
[0 or 1 / 1 / 1/step]
0: Permit (adjustment is done even toner
end condition)
1: Forbid (adjustment is not done at toner
end condition)
002 MUSIC *ENG
003 TC Adjustment *ENG
3520 [ITB Idle Rotation] DFU
001 Temperature: High *ENG
Specifies the idle rotation times of
the ITB after the process control.
[0 or 3 / 1.9 / 1 revolution/step]
002 Temperature: Medium *ENG
003 Temperature: Low *ENG
004 Temp.: L: ON *ENG
005 to
011
Adjusts the threshold temperature for entering the ITB idle rotation after the
process control.
005 Temp. Range Thresh:T2 *ENG
[20 or 30 / 25 / 1 deg/step]
006 Temp. Range Thresh:T1 *ENG
[0 or 15 / 15 / 1 deg/step]