System Service Mode
M065/M066 8-218 SM Appendix
3522
[Initial Process Control Setting]
Adjusts the threshold for the process control at power on.
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at power on is executed.
002 Non-use Time Setting *ENG
[0 to 1440 / 360 / 1 minute/step]
003 Temp. Range *ENG
[0 to 99 / 10 / 1 deg/step]
004 Relative Humidity Change *ENG
[0 to 99 / 50 / 1 %RH/step]
005 Absolute Humidity Change *ENG
[0 to 99 / 6 / 1 g/m
3
/step]
100
[Rapi Timer]
Time Setting *ENG
[0 to 255 / 30 / 1 sec/step]
Adjusts the time-out time to get the Rapi timer.
3531
[Non-use Time Process Control Setting]
Adjusts the threshold for the process control at stand-by.
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at stand-by is executed.
001 Non-use Time Setting *ENG
[0 to 1440 / 360 / 1 minute/step]
002 Temp. Range *ENG
[0 to 99 / 10 / 1 deg/step]
003
Relative Humidity
Change
*ENG
[0 to 99 / 50 / 1 %RH/step]
004
Absolute Humidity
Change
*ENG
[0 to 99 / 6 / 1 g/m
3
/step]
005
Maximum Execution
Number
*ENG
Adjusts the maximum execution time for
the process control at stand-by.
[0 to 99 / 10 / 1 time/step]