System Service Mode
SM Appendix 8-241 M065/M066
Appendix:
SP Mode
Tables
5501 [PM Alarm]
001 PM Alarm Level *CTL
[0 to 9999 / 0 / 1 / step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1
to 9999) x 1000 PM counter
5504 [Jam Alarm]
*CTL -
001
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".