System Service Mode
SM Appendix 8-283 M065/M066
Appendix:
SP Mode
Tables
076 Rotation (%): Fusing Roller
077 Rotation (%): Fusing Belt
078 Rotation (%):PTR Unit
079
[0 to 255 / - / 1 %/step]
Displays how much of the unit's expected lifetime has been used up.
Amt(%):ITB T-Collect Bottle
-091 to
-108
Displays the value given by the following formula:
(Current printouts ÷ Target printouts) × 100. This shows how much of the
unit's expected lifetime has been used up.
The Page% counter is based on printouts, not revolutions. If the number of
printouts reaches the limit, the machine enters the end condition for that unit.
If the revolution count lifetime is reached first, the machine also enters the
end condition, even though the Page% counter is still less than 100%.
091 Page (%): PCU: Bk
*ENG [0 to 255 / - / 1 %/step]
092 Page (%): PCU: C
093 Page (%): PCU: M
094 Page (%): PCU: Y
095 Page (%): Development Unit: Bk
096 Page (%): Development Unit: C
097 Page (%): Development Unit: M
098 Page (%): Development Unit: Y
103 Page (%): ITB Unit
*ENG [0 to 255 / - / 1 %/step]
104 Page (%): ITB Cleaning Unit
105 Page (%): Fusing Unit
106 Page (%): Fusing Roller
107 Page (%): Fusing Belt
108 Page (%): PTR Unit