Service Call
SM 6-13 M160/M161
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC530-00 D
Fusing fan error
The fan motor lock (rotating state) signal is sampled at 100 ms
intervals and the machine fails to receive the lock signal 50
times in succession.
Failed fan motor
Disconnected connector
Replace the fan motor.
Check the connector.
Replace the harness.
Replace the IOB.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC531-00 D
Development Cooling fan error
The fan motor lock (rotating state) signal is sampled at 100 ms
intervals and the machine fails to receive the lock signal 50
times in succession.
Failed fan motor
Disconnected connector
Replace the fan motor.
Check the connector.
Replace the harness.
Replace the IOB.