SC No. Level Error Name/Error Condition/Major Cause/Solution
SC818-00 D
Watchdog timer error
The system program fell into a bus-hold state or an endless
loop of the program interruption occurred, causing other
process to stop.
System program defective
Controller board defective
Optional board defective
Turn the main power off/on.
Replace the controller board.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC819-00 D
Fatal kernel error
[XXXX]: Detailed error code
Due to a control error, a RAM overflow occurred during system
processing. One of the following messages was displayed on
the operation panel.
System program defective
Controller board defective
Optional board defective
Replace controller firmware
[0x5032]
HAIC-P2 error
HAIC-P2 decompression error (An error occurred in the ASIC
compression/decompression module.)
[0x6261]
HDD defective
6261 6420 6469 7200 00 "bad dir"
[0x696e]
gwinit process ending
x69742064 "init died”
[0x766d]
VM is full
0x5f706167 "vm_pageout: VM is full”