SC No. Level Error Name/Error Condition/Major Cause/Solution
Reinstall the controller system software.
Replace the RAM-DIMM.
Replace the controller.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC821-00 D
Self-diagnostics error: ASIC
[XXXX]: Detailed error code
[0B00]
ASIC register check error
The write-&-verify check has occurred in the ASIC.
Defective ASIC device
Replace the controller board.
[0B06]
ASIC detection error
The I/O ASIC for system control is not detected.
Defective ASIC
Defective North Bridge and PCII/F
Replace the controller board.
[50A2]
Video bridge device (ASIC) register error 1
The CPU detects the video bridge device, but detects error data
from the video bridge device.
Defective I/F between the video bridge device and controller
Replace the controller board.