Service Call
SM 6-101 M160/M161
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC880-00 D
MLB error
The response is not received within the specified time during the
access to the MLB.
Defective MLB
Replace the MLB
Remove the MLB
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC881-01 D
Management area error
Defective software has been detected.
Abnormal accumulation of authentication information in the
software
Turn the main power switch off and on.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC899-00
D Software performance error (signal reception end)
-
Occurs when an internal program behaves abnormally.
In the case of a hardware defect
Replace the hardware.
In the case of a software error
Turn the main power off/on.
Try updating the firmware.