6.4.4 SCANNER, ARDF IMAGE ADJUSTMENT
Scanner Image Adjustment
Before the scanner adjustment, do the Side-to-Side registration and blank margin width
adjustment.
Use "Test Chart" to adjust this setting.
Magnification
A: Sub-scan magnification
1. Place the test chart on the exposure glass and make a copy from one of the paper feed
trays.
2. Check the magnification ratio. If necessary, adjust the magnification with the following
SP mode.
SP No. Name Specification
SP4-008 Sub-scan magnification ± 1.0%