Allowable Misregistration: 4.2 ± 2 mm (Leading edge) / 2 ± 1 mm (Left, right)
SP No. Name Range
SP6-006-001 Side-to-Side Regist: Front ± 2.0 mm
SP6-006-003 Leading Edge Regist: Front ± 5.0 mm
SP6-006-007 Rear Edge Erase ± 5.0 mm
Magnification
1. Place the temporary test chart on the ARDF and make a copy from one of the paper
feed trays.
2. Check the magnification and adjust it with SP6-017-001 if necessary.
SP No. Name Range
SP6-017-001 ADF Adjustment Magnification ± 5.0 %
6.4.5 PROBLEM AT REGULAR INTERVALS
Image problems may appear at regular intervals that depend on the circumference of certain
components.
The following diagram shows the possible symptoms (black or white dots at regular intervals or
other problems).
Problems Intervals Defective parts
Problems with the printed
result
29.9mm Charge roller
37.7mm Registration roller