SP Mode Tables
1105
[PrintTargetTemp]
Specifies the heating roller target temperature for coated paper (Center)
during printing.
1-105-023 C:Middle Thick E* [140 to 205 / 187 / 1deg/step]
1-105-025 C:Thick1(LowTemp) E* [140 to 205 / 185 / 1deg/step]
1-105-031 FuserOffMode E*
[0 or 1 / 1 / 1/step]
The switch that turns the fuser off after
the idle process runs over 30 minutes.
1106
[FusingTempDisp]
This SP displays the hot roller and pressure roller temperatures.
1-106-001 RollerCenter E
[-20 to 250 / 0 / 1deg/step]
Displays the current fusing thermistor
temperature (Center).
1-106-002 RollerEnds E
[-20 to 250 / 0 / 1deg/step]
Displays the current fusing thermistor
temperature (Ends).
1-106-003 MachinePowerOn E
[-20 to 250 / 0 / 1deg/step]
Displays the external temperature
measured at power ON, which is
detected with the temperature and
humidity sensor.
1135
[Inrush Control]
Enables or disables the setting of Inrush control (0: Disabled, 1: Enabled)
1-135-001 Inrush control E* [0 or 1 / 0 / 1 /step]