SP Mode Tables
3.3 MAIN SP TABLES-2
3.3.1 SP2-XXX (DRUM)
2001 [C biasControl]
2-001-001 C setting E
[-1350 to -900 / -1020 / 1V/step]
C: bias value.
This setting is available when
the bias control is OFF.
2-001-002 C(low) setting E
[-400 to -200 / -350 / 50V /step]
C(low): The value of C(low) output.
2-001-011 Vd_ref_lowhumi E
[-700 to -400 / -420 / 10V / step]
Displays or adjusts the target dark
potential (Vd) in the Env Division, low
humidity.
This setting is available when
the bias control is ON.
2-001-012 Vd_ref_midhumi E
[-700 to -400 / -430 / 10V/step]
Displays or adjusts the target dark
potential (Vd) in the Env Division, mid
humidity.
This setting is available when
the bias control is ON.
2-001-013 Vd_ref_highhumi E
[-700 to -400 / -470 / 10V/step]
Displays and adjusts the target dark
potential (Vd) in the Env Division, high
humidity.
This setting is available when
the bias control is ON.