Main SP Tables-2
M160/M161 3-14 SM Appendix
2105
[LED Emit Time Adj]
Adjusts the LEDA Light emission time.
2-105-001 Normal Speed E*
[50 to 200 / 100 / 1%/step]
2-105-002 Low Speed E*
2106
[LEDA Emit Time]
LEDA Light emission time.
2-106-021 Print:Normal E
[1000 to 8800 / 3000 / 1ns/step]
2-106-022 Print:Low E
2-106-023 Quenching:Normal E
2-106-024 Quenching:Low E
2109
[Test Printing]
Printing test patterns
2-109-001
Pattern
Selection
E
[0 to 17 / 0 / 1/step]
See the selections below. See also
page 3-233 for checking the procedure.
2-109-002 1 Sheet Printing E
[0 or 1 / 0 / 1/step]
2-109-003 Cont. Printing E
2-109-004 Print Side Select E
Selections for SP2109
0 None 9 Arg. Grid20mm
1 Vert. (1dot) 10 Indep. (1dot)
2 Hori. (1dot) 11 Indep. (2dot)
3 Vert/ (2dot) 12 Indep. (4dot)
4 Hori. (2dot) 13 Full
5 Grid Vert. 14 Band