004 Attack Max Num *CTL
Sets a limit on the number of requests received for
certification in order to slow down the certification
speed when an excessive number of access
attempts have been detected.
[50 to 200 / 200 / 1 attempt/step]
5420
[User Auth]
These settings should be done with the System Administrator.
Note: These functions are enabled only after the user access feature has been enabled.
041 Printer *CTL
Determines whether certification is required before
a user can use the printer applications.
[0 or 1 / 0 / -]
0: On, 1: Off
051 SDK1
*CTL
[0 or 1 / 0 / 1] 0: ON. 1: OFF
Determines
whether certification is required before
a user can use the SDK application.
061 SDK2
071 SDK3
5481
[Auth. Error Code]
This SP codes determines how the authentication failures are displayed.
001 System Log Disp *CTL
Determines whether an error code appears in the
system
log after a user authentication failure occurs.
[0 or 1/ 0 /1]
0: Off, 1: On
5501 [PM Alarm Interval] PM Alarm Interval
5501 001 Printout *CTL
Sets the PM alarm Interval.
[0 to 9999 / 0 / 1k prints/step]
The
alert is sent to the e-mail address that is specified
for the system administrator using a browser and
the built-in web server (Web Image Monitor).
0: Disables the PM alarm
When SP5-866-001 is set to "1", this SP is enabled.
Engine SP5-xxx