5504 [Jam Alarm]
5504 001
Jam Alarm *CTL
[0 to 3 / 3 / 1/step]
0: Disables the jam alarm
1: 1.5K, 2: 3K, 3: 6K
Sets the jam alarm level. If a paper jam occurs, the jam alarm counter increases by +1.
If no paper jam occurs while the set number of paper is output, the jam alarm counter
decreases by -1. The jam alarm occurs when the jam alarm counter gets to +10.
The alert is sent to the e-mail address that is specified for the system administrator using
a browser and the built-in web server (Web Image Monitor).
When SP5-866-001 is set to "1", this SP is enabled.
5505 [Error Alarm]
5505 001
Error Alarm *CTL
[0 to 255 / 7 / 1/step]
0: Disables the PM alarm
Sets the error alarm level. If an SC code occurs, the error alarm counter increases by +1.
If no SC code occurs while the set number of paper is output, the jam alarm counter
decreases by -1. The error alarm occurs when the error alarm counter reaches +5.
The alert is sent to the e-mail address that is specified for the system administrator using
a browser and the built-in web server (Web Image Monitor).
When SP5-866-001 is set to "1", this SP is enabled.
5507 [Supply Alarm]
5507 001 Paper Size *CTL
Enables or disables the supply alarm.
[0 or 1 / 0 / -]
0: Off, 1: On
5507 006 Waste Toner Bottle *CTL
Enables or disables the supply alarm.
[0 or 1 / 1 / -]
0: Off, 1: On
5507 007 Transfer Belt *CTL
5507 008 Fusing unit *CTL
5507 009 Cartridge *CTL
3. Appendix: SP Mode Tables
44