SC No. Level Error Name/Error Condition/Major Cause/Solution
SC544-01 A Fusing central thermopile high temperature detection (hardware)
In the event of an error
Triac defective (short-circuit)
Engine controller defective
Heating central thermopile defective
Fusing control software: out of control
If the triac is defective, replace the AC power supply board
If necessary, replace the BCU or the heating central thermopile
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC544-02 A Fusing central NC sensor high temperature detection (hardware)
In the event of an error
Triac defective (short-circuit)
Engine controller defective
Heating central thermopile defective
Fusing control software: out of control
Attach the new fusing unit, then run SP-5-810-002
If the triac is defective, replace the AC power supply board
If necessary, replace the BCU or the Fusing central NC sensor
Service Call 501-584