EasyManua.ls Logo

Ricoh MP C2504 - Page 1585

Ricoh MP C2504
1923 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-553-010 TransferIdleTime Rotation :End *ENG [0 to 3 / 0 / 0.1revolution/step]
3-553-011 Transfer Rotation Threshold:L1 *ENG [0 to 999999999 / 24000000 /
1mm/step]
3-553-012
Transfer Rotation Threshold:L2
*ENG [0 to 999999999 / 96000000 /
1mm/step]
3555 [ImageQuality Adj. Counter:Disp]
3-555-001 Charge AC Control *ENG [0 to 2000 / 0 / 1page/step]
3600 [Select ProCon]
3-600-001 Potential Control *ENG [0 or 1 / 1 / 1/step]
3-600-002 LD Control *ENG [0 to 3 / 1 / 1/step]
3-600-003 TC Adj. Mode *ENG [0 to 4 / 4 / 1/step]
3-600-004 ACC Before ProCon *ENG [0 to 3 / 2 / 1/step]
3-600-010 ActivePotentialControl *ENG [0 or 1 / 1 / 1/step]
3-600-030 IBACC:ON/OFF *ENG [0 or 1 / 1 / 1/step]
3-600-060 Vsg ITB Internal Circumference
Correction
*ENG [0 or 1 / 1 / 1/step]
3-600-080 Background Pot
ProCon:ON/OFF setting
*ENG [0 or 1 / 1 / 1/step]
3610 [Chrg AC Control]
3-610-001 Std Speed: K *ENG [0 to 3 / 2.2 / 0.01kV/step]
3-610-002 Std Speed: C *ENG
3-610-003 Std Speed: M *ENG
3-610-004 Std Speed: Y *ENG
3611 [Chrg DC Control]
3-611-001 Std Speed: K *ENG [300 to 1000 / 690 / 1-V/step]
3. Engine SP Mode Tables
350

Table of Contents