082
Target Temp. After Ready *ENG [140 to 165 / 155 / 1 deg/step]
Specifies the target temperature for the maintain mode after the machine has reached the
target temperature in warm-up mode.
083
Recovery Target Temp. *ENG [140 to 160 / 150 / 1 deg /step]
Specifies the target temperature for the print mode without printing/copying job after the
machine's recovery.
087 Thick 2: FC: Simplex: Ends *ENG
[130 to 180 / 160 / 1 deg/step]
088 Thick 2: BW: Simplex: Ends *ENG
089 Thick 3: FC: Simplex *ENG
[135 to 180 / 165 / 1 deg/step]
090 Thick 3: FC: Simplex: Ends *ENG
091 Thick 3: BW: Simplex *ENG
092 Thick 3: BW: Simplex: Ends *ENG
110 Middle Thick: FC: Duplex *ENG
[130 to 175 / 160 / 1 deg/step]
111 Middle Thick: BW: Simplex *ENG
112 Middle Thick: BW: Duplex *ENG
113 Middle Thick: FC: Simplex: Ends *ENG
114 Middle Thick: FC: Duplex: Ends *ENG
115 Middle Thick: BW: Simplex: Ends *ENG
116 Middle Thick: BW: Duplex: Ends *ENG
120 Plain2: FC: Simplex *ENG
[130 to 175 / 155 / 1 deg/step]
122 Plain2: FC: Duplex *ENG
124 Plain2: BW: Simplex *ENG
125 Plain2: BW: Simplex: Ends *ENG
126 Plain2: BW: Duplex *ENG
127 Plain2: BW: Duplex: Ends *ENG
8. Appendix: SP Mode Tables