003
Low Temp. Correction *ENG [0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the low temperature
condition (specified with SP1112-001) is detected, the value of this SP is added to the
heating roller temperature.
004
High Temp. Correction *ENG [0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the high temperature
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
005 Low Temp. Correction: Paper Feed *ENG [0 to 15 / 6.5 / 0.1 deg/step]
006
High Temp. Correction: Paper
Feed
*ENG [0 to 15 / 5 / 1 deg/step]
1113 [Stand-by Time]
001 After Ready *ENG [0 to 60 / 20 / 1 sec/step]
003
After Recovery *ENG [0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature after recovery (SP1105-083) without
any jobs.
004 After Job *ENG [0 to 60 / 10 / 1 sec/step]
005 PressureTemp: After Ready *ENG
[0 to 160 / 100 / 1 deg/step]
006 Pressure Temp: After Job *ENG
008 ON/OFF Time Switch *ENG [0 to 999 / 300 / 1 sec/step]
1115 [Stand-by Idling]
001
Interval *ENG [1 to 240 / 60 / 1 min/step]
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
002
Idling Time *ENG [1 to 60 / 2 / 0.1 sec/step]
Specifies the length of each idling operation during stand-by mode.
003
Idling Speed *ENG [0 to 1 / 0 / 1 mm/sec/step]
System Service Mode