1.SC Codes
94
2. Check the connectors of the harnesses related to upper limit detection (pickup roller lift sensor
(Tray 3) (SEN37) / pickup roller solenoid (Tray 3) (SOL3)).
Reconnect the connectors.
3. Check the electrical components related to upper limit detection (pickup roller lift sensor (Tray 3)
(SEN37) / pickup roller solenoid (Tray 3) (SOL3) / tray lift motor (Tray 3) (BM3)).
If they are defective, replace the components.
4. Check the harnesses (pickup roller lift sensor (Tray 3) (SEN37) / pickup roller solenoid (Tray 3)
(SOL3)).
If the harnesses are defective, replace the harnesses.
5. Replace the RYB.
6. Replace the IOB.
SC504-01
Error Name
A4 LCT Tray 1 Upper Limit Detection Error
Pattern
B
Error Condition
During tray initialization, the upper limit sensor fails to detect before the tray is lifted (the pick-up
solenoid is off) (five times consecutively).
Major Cause
ï‚· Power of downstream unit is not turned on.
ï‚· Pick-up solenoid (Tray 3) (SOL3) is defective or not connected properly.
ï‚· Pickup roller lift sensor (Tray 3) (SEN37) is defective or not connected properly.
ï‚· Harnesses are damaged.
Solution
In addition to checking for sensor/actuator defect by eye, also execute Input/Output Check as
necessary.
1. Check the connectors of the harnesses related to upper limit detection (pickup roller lift sensor
(Tray 3) (SEN37 / pickup roller solenoid (Tray 3) (SOL3)).
Reconnect the connectors.
2. Check the electrical components related to upper limit detection (pickup roller lift sensor (Tray
3) (SEN37 / pickup roller solenoid (Tray 3) (SOL3) / tray lift motor (Tray 3) (BM3).
If they are defective, replace the components.
3. Check the harnesses (pickup roller lift sensor (Tray 3) (SEN37 / pickup roller solenoid (Tray 3)
(SOL3)).