1.SC Codes
152
SC515-04
Error Name
LCT Exit Separation Motor Error
Pattern
B
Error Condition
The status of the release HP sensor when the LCT exit separation motor is running.
Major Cause
ï‚· Power of downstream unit is not turned on.
ï‚· LCT exit separation motor is defective, or is not connected properly.
ï‚· Release HP sensor is defective, or is not connected properly.
ï‚· The harnesses are damaged.
ï‚· PCB is defective
Solution
In addition to checking for sensor/actuator defect by eye, also execute Input/Output Check as
necessary.
1. Check the connectors of the harnesses (release HP sensor / LCT exit separation motor).
Reconnect the connectors. Turn the main power OFF and then ON.
2. Check the release HP sensor.
If it is defective, replace it. Turn the main power OFF and then ON.
3. Check the LCT exit separation motor
If it is defective, replace it. Turn the main power OFF and then ON.
4. Check the harnesses (release HP sensor / LCT exit separation motor).
If the harnesses are defective, replace the harnesses. Turn the main power OFF and then ON.
5. Replace the PCB. Turn the main power OFF and then ON.
SC515-05 to 14
Error Name
ï‚· 515-05: Vacuum Feed LCIT 1 Contact Motor Error
ï‚· 515-06: Vacuum Feed LCIT 2 Contact Motor Error
ï‚· 515-07: Tray 1 Vertical Transport Contact Motor Error
ï‚· 515-08: Tray 1 Vertical Transport Exit Contact Motor Error
ï‚· 515-09: Vertical Transport Entrance Contact Motor Error
ï‚· 515-10: Tray 2 Vertical Transport Exit Contact Motor Error
ï‚· 515-11: Tray 1 Vertical Transport Contact Motor Error