1.SC Codes
268
Replace the harness if it is not in good condition.
4. Board defective
Check if there are any traces of short circuit on the controller board. If so, replace it.
SC721-75
Error Name
Stacking Sponge Roller Lift Motor Error (Finisher SR5090/Booklet Finisher SR5100)
Pattern
B
Error Condition
ï‚· DC motor control error is detected (The first four times are reported as jams. An SC is issued when
it is repeated five times.)
ï‚· Home position is not detected within the specified time when moving to the home position. (The
first four times are reported as jams. An SC is issued when it is repeated five times.)
ï‚· Home position remains detected after a specified time after leaving the home position. (The first
four times are reported as jams. An SC is issued when it is repeated five times.)
Major Cause
ï‚· Power of downstream device is not turned on.
ï‚· Motor is defective
ï‚· Connector is not connected properly
ï‚· Short circuit
ï‚· Harness is damaged
ï‚· There is overload.
ï‚· Home position sensor defective
Corresponding components:
ï‚· Stacking Sponge Roller Lift Motor [DCM6]
ï‚· Stacking Sponge Roller HP Sensor [S32]
ï‚· Controller Board
Solution
1. Motor/sensor defective
Check the motor (whether it rotates on its own, whether its drive is transmitted, or if it is
overloaded). Check if the sensor turns off and on.
If the motor or sensor is not good, replace it.
2. Connector not connected properly
Check all the connectors of each motor and sensor are correctly connected. (controller board,
motor, sensor, relay)